  Using SBE - pneumatic airlamps in hazardous areas is very safe mode of illumination.
  pneumatic airlamp 26101  
     
  info info
    explosion- and flameproofed  
    VDE 0170 (SCH) f
VDE 0171 (Ex) s G5
BVS-Nr.:  T 3614
PTB-Nr.: III BIE-9920
 
    admission: EG-Richtlinie 94/9/EG
(ATEX-100a) applied.
 
  technical data  
    operating voltage:
ignition voltage:
electrical power:
luminous flux:
bulb:
operating pressure:
air consumtion:
ambient temperature:
weight:
length:
diameter:
air coupling:
120 V max.
210 V max.
80 W
3.800 Lm
80 W HQL
3 - 7 bar
300 L/min
-20°C  -  +40°C
11,5 kg
570 mm
220 mm max.
R3/4" / R5/8"
 
  example of use    
    Light fittings type 26101 are used where spacious working stations have to be illuminated with gright diffuse light
      - tunneling works
- tank - ships
- canalisation
   
    The lamps can be used in all hazardous areas zone 1.
  description    
    Due to its special construction an ignition of hazardous atmosphreres inside and outside the lamp are avoided by several means. At first the air flows into the lamp housing and generates an overpressure before it flows into the generator housing. housing to drive the turbine wheel of the AC-generator to induce the voltage for the bulb.
If the lamp housing or the protection glass is damaged, the air flows outside first. The generator stops immediately and cannot induce any voltage for the bulb.
The exhausting air prevents a penetration of explosive gases inside the lamp and can cool the spiral of a broken bulb, too.

Pressure-fluctuations of the air are compensated by the air regulating system inside the lamp. The lamp-housing is made of brass.
   